5.4.4

External control

You can control the EFOY Pro externally using a switching contact on Pin 7
at the Data Interface plug, e.g. a solar charger. See chapter 3.2
Connections on page 15 for the Pinning.
"External control" operating mode must be enabled.
Page 62
1.
Press
on the operating panel, or select
"Operating mode" in the main menu. The
operating mode selection appears.
2.
Select the "External control on" operating
mode.
3.
Press [ok] to confirm your selection.
An open padlock is displayed at the bottom right
of the display.
If the controller now receives an external signal
"RC" (Remote Control) is displayed at the bottom
right of the display.
INFO:
If you have not enabled external control,
a closed padlock is displayed at the
bottom right of the display when an
external signal is being received.
The unit starts disregarded the switch-on voltage
and charges the batteries until the set switch-off
parameters
Operation