EFOY Pro 12000 Duo Operation And Installation Manual page 37

Hide thumbs Also See for Pro 12000 Duo:
Table of Contents

Advertisement

Symbols on the display
The display shows different symbols depending on the operating status
and operating mode of the EFOY Pro fuel cell:
Current battery voltage.
Current charging current of the EFOY Pro fuel cell.
Fill level of the fuel cartridge.
A cluster icon is displayed for EFOY Pro devices that run in
parallel (see chapter 8.5 "Cluster Controller CC1" on page 91).
If want to operate the EFOY Pro fuel cell using an external
controller, the external control function must be enabled (see
chapter
page 62). If this is not enabled, a padlock symbol appears
(Factory defaults).
If the external control is switched on, an open padlock appears
at the bottom right of the display.
If you have switched external control on and the device is in
"Remote Control" mode, "RC" (Remote Control) appears at the
bottom right of the display.
If the battery type was changed via the expert menu to Lithium
iron phosphate (LiFePO4), a LiFe-icon appears top right on the
display (see chapter 5.1.5 "Expert menu" on page 44).
The altitude is above 3,000 meter. The icon appears on the right
on the display. Air pressure-induced power reduction is possible.
MODBUS RTU was selected as communication protocol. "M"
appears at the bottom right of the display (see chapter 5.1.5
"Expert menu" on page 44, under point communication.
Page 36
INFO:
The fuel gauge for the fuel cartridge is just an indicator
and calculates the methanol consumption. The FS1 fuel
cartridge sensor must be used to measure the actual fill
level. The fuel cartridge should only be replaced once it
has been completely emptied.
5.4.4
"External
control"
Operation
on