Recommended way to read expert setting parameter:
1.
Write (command 0x10) desired expert setting ID to MODBUS
Register 40990 (IDSELECT)
2.
Use a combined read & write (command 0x17), write setting
property to read to 49999 (IDSTATESEL) and read 40991
(IDVALUE).
Recommended way to write expert setting parameter:
1.
Write (0x10) desired expert setting ID to MODBUS register 40990
(IDSELECT)
2.
Write desired value to 40991 (IDVALUE) using command.
8.2.2

SIO / Plain text

Following commands are available in the clear text protocol:
Command
?
BATTERY
BATTERYPROTECTION
BUTTON
CARTRIDGE
CONFIG
DEFAULT
ERROR
FUELGAUGE
GET
HYBRID
LANGUAGE
LIMITS
LOCKED
LOG
MODBUS
PROFILE
REMOTE
RESET
Page 88
Data Interface and Optional Accessories
Description
Display command overview.
Select battery type
Control battery protection
Software control of device
Set/view connected fuel cartridges/DuoCartSwitch
Set customized operation parameters
Apply default operation parameters
Show ten most recent errors
Enable/disable fuel gauge
Get customized operation parameter
Switch the device from automatic into hybrid mode for
15s
Set language in Operating panel OP2
Show min. and max. values of operation parameters
Lock control contacts
Show details of current operation state
Settings of MODBUS protocol
Select voltage profile
Remote control via software interface
Restart the device