Operation
5.6

Shutdown

5.6.1

Switching off the fuel cell

Switch off the EFOY Pro fuel cell via the operating panel or directly on the
device. This is described in chapter 5.4.3 "Manual Off" on page 61.
5.6.2

Removing the EFOY fuel cartridge

This is described in "Removing the fuel cartridge" on page 56.
INFO:
Protect the fuel cartridge and the fuel cartridge connector on the device
from impurities.
5.6.3

Secure transportation and storage procedure

For a secure transport and storage the secure transport and storage
procedure has to be executed, especially when the EFOY Pro 12000 Duo
fuel cell is exposed temperatures below +1 °C / +34 °F.
The following items are required for this procedure:
Resealable canister (2 liter)
Isolated hexagon socket screw key (Allen key)
Methanol-resistant gloves
Safety goggles
Follow the instructions shown on the display:
1.
Shut down EFOY Pro 12000 Duo via
"Manual Off" and let the unit cool down.
2.
Press [menu] and [] for at least 3
seconds.
3.
Put the resealable 2 liter canister under
the opening screw on the bottom and
unscrew the outlet screw.
Page 65