Data Interface and Optional Accessories
8.2.1.1 MODBUS RTU functions
The EFOY Pro MODBUS protocol is based on following Modbus
specifications:
Modbus application protocol V1.1b3
Specific feature: Type RTC (Real Time Clock)
Use following bit field definition for decoding RTC types (e.g. system time
and date):
struct {
unsigned long second : 6; // seconds 0 to 59
unsigned long minute : 6; // minutes 0 to 59
unsigned long month
unsigned long hour
unsigned long day
unsigned long year
};
Read Device Identification (Function code 0x2B)
Read out system information
Object
Name
ID
0x00
VendorName
0x01
ProductCode
0x02
MajorMinorRevision
0x03
VendorUrl
0x04
ProductName
0x06
UserApplicationName
Input Register (Function code 0x04)
Address
Name
30001
Tst
30005
Twt
30007
Tdcdc
30009
Tpcb
30011
Tres
30013
Taux
30015
Ubat
: 4; // month 1 to 12
: 5; // hour 0 to 23
: 5; // day 1 to 31
: 6; // year - 2000 (max. 63)
Example
SFC Energy AG
400100-1525-00001
19.08
http://www.sfc.com/
EFOY Pro Series
Firmware EFOY Pro 12000
Duo V01 19.08I24V/48V QB
date 2016-03-24
Description
Stack temperature
Heat exchanger temperature
Periphery temperature
Periphery temperature
Periphery temperature
Reservoir temperature
Battery voltage
Type
STRING
STRING
STRING
STRING
STRING
STRING
Unit
Multiplier
Type
°C
0.001
INT32
°C
0.001
INT32
°C
0.001
INT32
°C
0.001
INT32
°C
0.001
INT32
°C
0.001
INT32
V
0.001
UINT16