5.6.4

Detaching the charge line and data line

1.
Switch off the voltage connection between EFOY Pro and the
battery via the switch off switch.
2.
Disconnect the electrical connection afterwards.
INFO:
Store the plugs and cables in a cool, dry place.
5.6.5

Detaching the exhaust hose

Disconnect the exhaust hose. Protect it from impurities and seal the
exhaust outlet with the protective cap.
CAUTION!
Store the EFOY Pro fuel cell in a cool place, but at a temperature over
+1 °C / +34 °F. (See also storage temperature in chapter 3.3
"Specifications" on page 18).
If the EFOY Pro fuel cell is exposed to temperatures below +1 °C / +34 °F
without connected batteries and sufficiently filled fuel cartridges, it must
be defrosted for approximately 24 hours at room temperature before use.
INFO:
Use a suitable box for storing the EFOY Pro fuel cell, e.g., the box
in which it was delivered. The EFOY Pro fuel cell must be stored in
an upright position only.
Page 66
4.
This procedure can take at least up to 5
minutes. After completing the procedure
a message will be shown in the display.
5.
Rescrew in the outlet screw and dispose
the fluid under acceptance of national
allowance.