Data Interface and Optional Accessories
Via Operating panel OP2:
Display in Operating
panel OP2
Baud rate
Data bits
Parity
Stop bits
Via PC or Laptop:
With the SIO command "MODBUS" the configurations can be adjusted as
well as the MODBUS RTU protocol can be activated.
A detailed description is available in the user manual for the interface
adapter.
Connection to a RS485 network
An RS485 interface is provided at the data interface back side of the EFOY
Pro 12000 Duo.
INFO:
The pre-installed MODBUS Address is the last 2 numbers of the serial
number. The EFOY Pro with serial number 123456-1234-56789 has the
address 89. In the case where the serial number ends with 00 the address
100 is set.
1.
Press and hold [ok] and [menu] at the same
time for 2 seconds. The expert menu
appears.
2.
Press [] to select a submenu
"Communication" and press [ok] to access.
3.
Select a submenu "MODBUS Config" and
press [ok].
4.
Press [][] to select one of the following
MODBUS configurations. Press [ok] to
confirm.
Following configurations are available:
9600 8,E,1
9600 8,O,1
(Standard)
9600
9600
8
8
Even
Odd Parity
Parity
1
1
9600 8,N, 2
9600 8,N,1
9600
9600
8
8
No Parity
No Parity
2
1
Page 79