Installation
4.5
Fill in EFOY Initial Start Fluid
CAUTION!
Do not get in contact with the EFOY Initial Start Fluid. Wear methanol-
resistant gloves and safety goggles when filling in EFOY Initial Start
Fluid.
The content of the fluid is 0.5 mol/l dissolution of distilled water and
methanol and is not harmful in small amounts.
For a secure transport and storage the EFOY Pro 12000 Duo is shipped
empty. Therefore it is necessary to fill in EFOY Initial Start Fluid before
initial operation. The content of the fluid is 0.5 mol/l dissolution of
distilled water and methanol.
CAUTION!
Note that liquid can drop out when filling in EFOY initial start fluid.
1.
Use a clean pair of scissors to cut off
the tip of the bottle.
2.
Put on the filling tube onto the tip.
The EFOY Initial Start Fluid bottle
is for one time use only.
3.
Unscrew the opening screw for
EFOY fluids (EFOY fluids only) with 6
mm allen key. Keep the screw close
for further use.
4.
Insert the tube into the connection
nozzle on the device until the mark.
5.
Turn the bottle upside down above
the fuel cell and slowly squeeze the
entire content into the opening.
Page 29