Data Interface and Optional Accessories
8.6

DuoCartSwitch DCS 1

A
CAUTION!
Only connect one DuoCartSwitch to each RJ45-plug (Remote Control /
Data Interface).
If both DuoCartSwitch are connected to one RJ45-plug the switching of
the DuoCartSwitch fuel connectors malfunctions, which might damage
the EFOY Pro fuel cell.
A detailed description is available in the user manual DuoCartSwitch
DCS1.
The DuoCartSwitch enables you to connect
two fuel cartridges to the cartridge
connector of one EFOY Pro fuel cell. The
switching valve switches automatically
from the fuel cartridge in operation to the
reserve fuel cartridge. This means that the
autonomy of the application can be
doubled.
1.
Screw the fuel-cartridge connector of
the EFOY Pro on the DuoCartSwitch.
B
2.
Connect one DuoCartSwitch via a port
doubler to each RJ45-plug of the EFOY
Pro:
3.
For activation of the DuoCartSwitch
see chapter 5.1 "Operation via the
operating panel" on page 35.
- A: Remote Control plug
- B: Data Interface plug
Page 93