Manual On - EFOY Pro 12000 Duo Operation And Installation Manual

Hide thumbs Also See for Pro 12000 Duo:
Table of Contents

Advertisement

5.4.2

Manual On

You can switch the device on manually if the battery voltage is below 26.4 V
/ 52.8 V (Lead batteries) or 28.0 V / 56.0 V (LiFePO4). After the start phase,
the device is then in "charging mode".
The device operates independently of the configured switch-on voltage,
and charges the battery until the cut-off threshold is reached.
(U
>28.8 V / 57.6 V and I
batt
Please note: The EFOY Pro fuel cell can only start if it is connected to an
intact battery and a filled fuel cartridge. The EFOY Pro fuel cell does not
switch on if the battery is damaged or has been deeply discharged.
Page 60
< 10.0 A / 5.0 A)
off
1.
Press
on the operating panel, or select
"Operating mode" in the main menu. The
operating mode selection appears.
2.
Select the "Manual On" operating mode.
3.
Press [ok] to confirm your selection.
Operation

Advertisement

Table of Contents
loading