REP 5.1 A6 Control Panel and/or
Control Panel Assembly
Parts List on PL 5.2
Removal
CAUTION
Follow electrostatic discharge precautions
(Section 6). Static electricity can damage this
component.
1. Remove power cord.
2. Remove document catch tray assembly
(REP 1.1).
3. Remove coupler cover (REP 1.3).
4. Remove LH cover (REP 1.4).
5. Remove scan support assembly.
6. Remove control panel assembly.
a. Disconnect J111 at A0 CNC PWB.
(Figure 1)
b. Remove screw securing ground wire
to LH frame.
c. Remove
control
panel
harness from cable clamp.
d. Remove remaining screw securing
control panel assembly to upper scan
cover.
e. Raise control panel assembly above
upper scan cover. (Figure 2)
f.
Thread
control
panel
harness through the cutout in upper
scan cover.
REP 5.1
assembly
assembly
www.printcopy.info
Replacement
12/88
4-42
1. Replace overlays as needed.
2. Reinstall in reverse order.