Glossary of Mnemonics
ABC
Abandon Call
CABS1
Cable equalizer selection = 1.8Km
CABS2
Cable equalizer selection = 3.6Km
CDG
Completed (Dial) DTMF Generation
CED
Called Station Identification
CFR
Confirmation to Receive
CIG
Calling Subscriber Identification
CIL
Call Indicator Low
CLI
Signal Collision Indication
CNG
Calling Tone
CNT
Connect Telephone Line to Modem
CRP
Command Repeat
CSI
Called Subscriber Identification
CTC
Continue to correct
CTR
Response to CTC
DAG
Request Diagnosis
DCN
Disconnect
DCS
Digital Command Signal
DE6
1650 Hz. Signal Detection
DE8
1850 Hz. Signal Detection
DIS
Digital Identification Signal
DTC
Digital Transmit Command
DTMF
Dual Tone Multiple Frequency
EOD
End of Dialed Data
EOM
End of Message
EOP
End of Procedure
EOR
End of of Retransmission
EOR-NULL Indicate the next block transmission
ERR
Respond to EOR
EQM
Line Quality
FCD
Facsimile coded data
FCF
Facsimile Control Field
FCS
Frame checking sequence
FIF
Facsimile Information Field
FTT
Fail To Train
GC
Group Command
GI
Group Identification
HDLC
High Level Data Link Control
ICN
Telephone Line connected to
Modem
IGD
Self check Indication "Good"
IL1
Loop 1 Made
IL2
Loop 2 Made
ING
Self check Indication "No Good"
IOT
Telephone Line Open Indication
Glossary of Mnemonics
IRI
Illegal Instruction
J3L EQL Japanese 3 Link Equalizer
LCS
Line Conditioning Signal
MF
Mini fax
MH
Modified Huffman
MCF
Message Confirmation
ML1
Make Loop 1
ML2
Make Loop 2 and 1644 Hz. Touch
tone Signal Sent.
MPS
Multi-Page Signal
MTF
Modulated Transfer Function
NSC
Non-Standard Facilities Command
NSF
Non-Standard Facilities
NSS
Non-Standard Set-Up
OPT
Open a Telephone Line (initial state)
PHP
Phasing Period
PIN
Procedural Interrupt Negative
PIP
Procedural Interrupt Positive
PIS
Procedure Interrupt Signal
PPR
Partial page request
PPS
Partial page signal
PPS-NULLPost message command for Partial
page signal
PRD
Preparation for Dialing
PRI-EOM Procedure Interrupt-EOM
PRI-EOP Procedure Interrupt-EOP
PRI-MPS Procedure Interrupt-MPS
PST
Prepare to Send Tone
PTN
Send Telephone Number (from
Main to Coupler PWB)
RR
Receive ready
RCP
Return to control for partial page
RED
Redial
RGD
Request to Generate DTMF
RNR
Receive not ready
RTN
Retrain Negative
RTP
Retrain Positive
RL EQL
Receive Link Amplitude Equalizer
SLF
Self check
SST
Prepare to Send Single Tone
T2 EQL
Two baud taps Equalizer
TCF
Training Check
TSI
Transmitting Subscriber
Identification
TL EQL
Transmit Link Amplitude Equalizer
ZZF
German Configuration 6 Standards