Art. No.: 72801001
Appendix
Step
3
4
Procedure
Fig. 13-2: Flexbracket-deflector installation
If a mounting rail is already mounted under the system unit, disconnect the
fixing bolts and remove the mounting rail. (see Fig. 13-3).
Fig. 13-3: Disassembly mounting rail
The slide of the Flexbracket must be pull in such a position that the
borings for the insertion and tightening of the fixing bolts are available.
Furthermore the pull spring at the Flexbracket must be push away
laterally.
Set the fixing bolts in the counterbore of the Flexbracket. Positioning the
Flexbracket on the system unit and tighten. (see Fig. 13-4).