8.29 Configurable in- and outputs

The in- and outputs of the iJET Pro version allow multitude of
configurations. For example it's possible to display signals over the
M8-connector for status signals (OK, Warning, Failure) information
of the ink cartridge level (low, 5%/empty), print ready and print
pulse.
On the input side signals for heating, spitting, print direction, upside
down, print stop and text selection may be charged.
If external text selection is used the texts for input 1 must be
named „!EXT01.00I" and „!EXT02.00I".
The texts „!EXT01.00I" to „!EXT04.00I" can be assigned if both
inputs are used..
The setting can be selected by the iDesign software under
Functions
System Settings
Encoder I/O config, or by the Web-Browser under Settings
Advanced Settings
Sensor Opt.IO/Encoder Opt IO.
CAUTION!
If outputs will be activated, don't hot-wire them, i.e.
by a connected sensor or encoder-output!
Use splitter cable.
Fig 21: Settings in- and outputs