Boot Loader Update - Weber Markoprint iJET Operating Manual

Inkjet coder
Table of Contents

Advertisement

Art. No.: 72801001
Appendix

13.8 Boot loader update

A boot loader update of the system unit is carried out as
follows:
CAUTION!
The system may under no circumstances be switched
off during the boot loader update.
If the update cannot be completed, do not restart the
system.
To replace the boot loader the system must then be
send to the manufacturer.
The Boot loader version will be shown in the start screen
down right, during the Bluhm/Weber logo run through the
screen.
1.
Switch on the system and keep the iLOGIK button pressed
when the start logo (Bluhm/Weber, iJET) appears.
2.
The following then appears on the screen:
Prg: 0 PV1.0xx current program versions
GA.: 0GV0.032  current gate array version
Stick?
3.
Insert the USB stick with the new version.
4.
The following then appears on the display:
Prg: 57 PV1.0xx current program versions
GA.: 14 GV0.032 current gate array versions
Start?
5.
By briefly pressing the iLOGIK button the new boot loader
version is copied to the internal memory.
6.
The green power LED lights up during the copying process.
7.
Wait until the end of the copying process, with the power LED
lit up and the sensor LED displayed in green! If this process
is prematurely interrupted the system will no longer start!
8.
Restart the system by switching off the voltage and switching
on again.
Page 106 of 127