Setup Wizard [Advanced System Configuration]
HEATERS
Tap Yes then Next to configure a new heater (Tap No then Next to continue to
Configure Pumps).
Create: Tap Create then Next to select a new heat source type (Gas, Solar, Heat
Pump, UltraTemp or Hybrid) and configure the selected heat source settings.
Heater Name: Enter a name for the heater.
Affiliated Body: Pool, Spa, or Pool and Spa.
Modify: Tap Modify then Next to display the list of configured heaters. Tap New
Pump to add a heat source. From this screen you can add or delete a heat source
from the list. When finished with setting up heater source settings, tap Next to
continue to the Configure Valves screen.
+ Add Heater: Tap Add Heater to display the available heaters. When finished
configuring up the heater settings. Tap Next to continue to the Configure Remotes
screen.
REMOTES (SPA-SIDE)
QuickTouch Remote: See page
• To setup a QuickTouch remote, select Yes. If there is no QuickTouch remote
installed, select No and tap Next to continue.
• Remote Name: You can change the name of the remote and assign the remote's
four buttons equipment functions to control.
• Enable Remote ON/OFF): To enable the remote select ON. Tap Next to continue.
• Button Assignments: Tap Configure. Tap Button 1, then tap the AUX circuit
button for this circuit. Tap Back and repeat for buttons 2-4. When all buttons
have been assigned, tap Return arrow until SpaCommand remote screen is
displayed. Tap Next to continue.
iS4 Remote:
See page
• To setup an iS4 remote, select Yes. If there is no iS4 remote installed, select No
and tap Next to continue.
• Remote Name: If needed, you can change the name of the remote.
• Enable Remote ON/OFF): To enable the remote select ON. Tap Next to continue.
• Button Assignments: Tap Configure. Tap Button 1, then tap the AUX circuit
button for this circuit. Tap Back and repeat for buttons 2-4. When all buttons
have been assigned, tap Return arrow until SpaCommand remote screen is
displayed. Tap Next to continue.