Pentair IntelliCenter User Manual page 75

For pool and spa
Hide thumbs Also See for IntelliCenter:
Table of Contents

Advertisement

Pumps (IntelliFlo
Circuits (1-8)
Add Circuit
Pool
Booster Pump
WF Pump
Affiliated Circuit Settings
Circuit
Typr
Flow (GPM)
Pump Status
GPM
70
1600 RPM
No Problems Detected
Pump appears to be running normally. Click
here to view possible issues not being detected.
VSF)
®
1000 RPM
2500 RPM
1340 RPM
AUX3
GPM
40
100
Speed Circuits: Assign the
speeds to the circuits you wish to use.
Tap Speed Circuits and tap Add Circuits
to assign a new AUX circuit. To change
the pump speed, tap the AUX name to
change the assigned RPM setting. Tap
Return to save the setting and return to
the previous screen.
Affiliated Circuit Settings:
Circuit: The assign circuit to control
the pump speed.
Flow (GPM): Assign pump flow rate
from 20-140 for the selected circuit.
Speed (RPM): Assign pump speed from
450 to 3450 for the selected circuit.
Pump Status: Shows the current
power usage in Watts, flow rate
in gallons per minute (GPM) or
revolutions per minute (RPM) while
the pump is operating. Tap Return to
return to the previous screen. Also
see: Tap Status on the Home screen to
display the current pump status and
error condition.
IntelliCenter Control System User's Guide
| 67