Valve Actuators Circuit Assignments: The IntelliCenter™ Control System can
control up to four automatic valve actuators (for shared equipment). Six (6) more
can be added with Valve Expansion Cards. Two of the valve outputs are dedicated to
the pool/spa intake (INTAKE) and return (RETURN) valves. Valve A or Valve B
actuators are for general purpose use (solar, water-feature, in-floor cleaner, etc.).
Note: Valve A may not be used with any other circuit when Solar is selected
as a heat source. Note: When using solar heat, note that for shared equip-
ment pool and spa combination, Valve A is always used for solar. For dual
body dual equipment, Valve A is for pool, and Valve B for spa. Installing the
optional Valve Expansion Card provide an additional six (6) valve actuators (C, D,
E, F G). See IntelliCenter Control System Models in Settings > Advanced System
Configuration > Installation Setup > Body Configuration, see page 55.
Also see Valve Delays: For Valve delay and Heater Cool Down settings and Freeze
Cycle Time, see Settings > Advanced System Configuration > Delays on page 87.
For Pool and Spa Shared Equipment: Return valve actuator (pool), Spa Return.
Intake Valve Actuator (Pool Drain/Skimmer, Vacuum Line, Spa Drain/Skimmer).
Valve A
Valve B
Intake
Return
Valve A (XPC0)
Valve A Settings
Valve Type
Valve Name
Assigned Circuit
Select Circuit
Spa
AUX 2
AUX 4
AUX 5
IntelliCenter Control System User's Guide

Valves

Standard
Standard
Standard
Standard
Standard
Standard
Valve A
filter pump
AUX 1
AUX 3
Filter Pump
AUX 6
Note: Valves A & B and Solar Heating:
For Single Body systems, Valve A is
used for SOLAR if you choose SOLAR
heating. For Dual Body systems, Valve
B is used for SOLAR if you choose
SOLAR HEATER.
VALVE A Settings: Standard
(2-Way/3-Way). Note: For Single Body
systems, Valve A is used for SOLAR if
you choose SOLAR HEATER. Valve A is
displayed if additional valve circuits are
available (Depending on the Personality
Card installed, see page 106.
Valve Name: Tap Valve A name to
change the valve name.
Assigned Circuit: Assign the Pool
circuit for VALVE A.
VALVE B Settings: Standard
(2-Way/3-Way). Note: For Single Body
systems, Valve B is used for SOLAR if
you choose SOLAR HEATER. Valve B (1)
is displayed if additional valve circuits
are available (Depending on the Person-
ality Card installed, see page 106.
Valve Name: Tap Valve B name to
change the valve name.
Assign Circuit: Assign the Spa circuit
for VALVE B.