ETC Ion Operation Manual page 254

Hide thumbs Also See for Ion:
Table of Contents

Advertisement

Update Dialogue Box
When you press [Update], a dialogue box will open in the CIA. Update styles and modifiers for those
styles will be divided in the Update Dialogue Box.
Note:
(on page 143)
Note:
more information.
Update Styles
{All} - this button will update the target cue and all references stored to that cue (nested and
otherwise).
{Make Absolute} - this button will update the target cue and convert all levels to absolute val-
ues, thereby removing any references.
{Ref Only} - this button will only update the palettes or presets used in the cue, but will not
update the cue itself. If a manual reference was used before using {Ref Only}, the last manual
reference will be updated.
Update Modifiers
{Last Ref} - this button will update using the last reference that was applied.
{Break Nested} - this button will update the target cue and any presets used, but breaks the ref-
erence to any palettes nested in a preset. For example, if cue 1 channel 1 references preset 3,
and preset 3 was built using color palette 5. When updated with this option, preset 3 would
be updated, color palette 5 would not, and the reference to CP5 would be broken in preset 3.
{Reset Update} - this button will clear any commands after the [Update] command to quickly
undo pending changes before [Enter] is pressed.
The dialogue box also provides you with a listing (by record target) of what channels/parameters will
be impacted by the update instruction. If the channel contains a reference in the cue, it is indicated.
Channels that have been manually added to the stage output, but are not overrides of an active cue
will update to the selected cue list.
Once you have made a selection from the available options, press [Enter] and the target will be
updated.
Targets may be deselected from the dialogue box, excluding them from the update without spe-
cifying the target number, for example, [Update] [Color Palette] [Enter]. Selecting a line by clicking or
pressing it can also be used to deselect a target.
252
Default Update Modes are set in Setup>User>Record Defaults. See
for more information.
{By Type} is available as a softkey. See
Updating By Type Presets (on page 227)