ETC Ion Operation Manual page 125

Hide thumbs Also See for Ion:
Table of Contents

Advertisement

Dimmer List for CEM+, CEM3, and FDX 2000/3000
Note:
CEM3 v1.3.1 and newer, and FDX v3.4.0 and newer.
To use the Dimmer Feedback area of the Device List, you must first enable feedback. In the network
tab of the ECU, when using CEM+ or CEM3, make sure {Sensor/FDX3000 Feedback} is enabled, or
when using FDX 2000/ 3000, make sure that {Sensor/FDX3000 Feedback} or {FDX2000 Feeback} is
enabled. The default setting is disabled for both. See
Open the Dimmer Feedback display while in the Patch display by pressing {Device List}> {Dimmers}.
When the dimmer list is opened, the dimmers will be displayed in Patch by Address mode.
Ion will display the following information that it receives from the dimmers:
Address
Channel
Label
System
Rack
Lug
Module Type
Firing Mode
Control Mode
Curve
Recorded Loads
Note:
Patch
For Dimmer Feedback, these software versions are required: CEM+ v3.0 and newer,
The System ID number from CEM3 is not currently supported.
Interface Protocols (on page 458)
123

Advertisement

Table of Contents
loading

Table of Contents