Type Codes for Output Devices
Type Code
CONTROL
RELAY
BELL CIRCUIT
STROBE CKT
HORN CIRCUIT
AUDIBLE CKT
SPEAKER
REL END BELL
blank label
REL CKT ULC
RELEASE CKT
REL AUDIBLE
TELEPHONE
REL CODE
BELL
INSTANT RELE
ALARMS PEND
CONTROL NAC
GEN ALARM
GEN SUPERVIS
GEN TROUBLE
GENERAL
PEND
TROUBLE PEND
NFS-640 Programming Manual P/N 51333:B 10/03/2003
www.PDF-Zoo.com

NAC and Panel Circuit Type Codes

A comprehensive list of Type Codes for panel NACs and Panel Circuits. The Type Codes that display,
however, depend on the type of circuit: NAC or Panel Circuit relay. For instructions on programming
Type Codes, refer to "How to Modify or Delete a Point (2=point)" on page 21.
Note: Do not assign Releasing Type Codes to Panel Circuits with the exception of the audible Type Codes REL END
BELL and REL AUDIBLE.
Silenceable
Configuration
(Y/N)
Y
Panel Circuit relay or NAC
Y
Panel Circuit relay
Y
Panel Circuit relay or NAC
Y
Panel Circuit relay or NAC
Y
Panel Circuit relay or NAC
Y
Panel Circuit relay or NAC
N
Panel Circuit relay only
N
Panel Circuit or NAC
Y
Panel Circuit relay or NAC
N
NAC
N
NAC
Y
Panel Circuit or NAC
N
Panel Circuit relay only
Y
NAC only
N
NAC
N
Panel Circuit or NAC
Y
Panel Circuit relay or NAC
N
NAC
N
NAC
N
NAC
N
NAC
N
NAC
Table 35 NAC and Panel Circuit Type Codes
Device Function
Supervised NAC
Relay output
Supervised NAC for notification appliance
Supervised NAC for notification appliance
Supervised NAC for notification appliance
Supervised NAC for notification appliance
Supervised NAC for speaker circuits
Supervised NAC
Supervised NAC for undefined device
Releasing Circuit, power-limited, supervised for opens, shorts and ground
faults (always non-silenceable)
Releasing circuit, nonpower-limited, supervised for opens and ground faults
NAC, activated upon release
Standard Telephone circuit
Supervised NAC (NFS-640 NAC only)
NAC, short = normal; supervised for open circuits and ground faults. Always
non-silenceable and switch-inhibited.
Output that will activate upon receipt of an alarm condition, and remain in the
alarm state until all alarms have been acknowledged. It is programmed as "switch
inhibit".
Supervised NAC
Control Module, an XPC-8 circuit, or an
Municipal Box Transmitter for NFPA 72-1999 Auxiliary Fire Alarm Systems
applications (MBT-1 required). This Type ID can also be used for general alarm
activation. It is programmed as "switch inhibit".
Control Module, an XPR-8 relay, or an
any Supervisory condition (includes sprinkler type). It is programmed as "switch
inhibit".
Control Module, an XPR-8 relay, or an
any System Trouble condition. It is programmed as "switch inhibit".
Control Module, an XPC-8 circuit, or an
activate upon receipt of an alarm and/or trouble condition, and remain in the
ON state until all events have been ACKNOWLEDGED.
Control Module, an XPC-8 circuit, or an
activate upon receipt of a trouble condition, and remain in the ON state until all
troubles have been ACKNOWLEDGED. It is programmed as "switch inhibit".
Appendix F: Type Codes
XP5-C
(in NAC mode) configured as a
XP5-C
(in relay mode) activated under
XP5-C
(in relay mode) activated under
XP5-C
(in NAC mode) that will
XP5-C
(in NAC mode) that will
107