Acs Selection Group J (Slc #1); Acs Selection Group K (Slc #2); Acs Selection Group L (Slc #1 And #2) - Notifier NFS-640 Programming Manual

Fire alarm control panel
Hide thumbs Also See for NFS-640:
Table of Contents

Advertisement

2. Program Change

ACS Selection Group J (SLC #1):

Note: Point number to Detector number relationship is sequential. To determine Point to Detector relationship add 64
to Point number to arrive at Detector number.

ACS Selection Group K (SLC #2):

Note: Point number to Detector number relationship is sequential. To determine Point to Detector relationship add 64
to Point number to arrive at Detector number.

ACS Selection Group L (SLC #1 and #2):

Note: 1- Point number to Detector number relationship is sequential. To determine Point to Detector relationship add
128 to Point number to arrive at Detector number.
Note: 2- Point number to Detector number relationship is sequential. To determine Point to Detector relationship add
96 to Point number to arrive at Detector number.
38
www.PDF-Zoo.com
Point
Type
Red LED
1
Input
Detector 065 Alarm
2
Input
Detector 066 Alarm
3
Input
Detector 067 Alarm
to
64
Input
Detector 128 Alarm
* Pressing the switch button when the Switch Function is "Not Used" will cause the associated LED to stop
blinking. This is a local acknowledgement at the annunciator only: no message is sent to the panel.
Point
Type
Red LED
1
Input
Detector 065 Alarm
2
Input
Detector 066 Alarm
3
Input
Detector 067 Alarm
to
64
Input
Detector 128 Alarm
* Pressing the switch button when the Switch Function is "Not Used" will cause the associated LED to stop
blinking. This is a local acknowledgement at the annunciator only: no message is sent to the panel.
Point
Type
Red LED
1
Input
SLC 1, Detector 129 Alarm
2
Input
SLC 1, Detector 130 Alarm
3
Input
SLC 1, Detector 131 Alarm
to
31
Input
SLC 1, Detector 159 Alarm
32
Not Used
33
Input
SLC 2, Detector 129 Alarm
34
Input
SLC 2, Detector 130 Alarm
35
Input
SLC 2, Detector 131 Alarm
63
Input
SLC 2, Detector 159 Alarm
64
Not Used
* Pressing the switch button when the Switch Function is "Not Used" will cause the associated LED to stop blinking. This
is a local acknowledgement at the annunciator only: no message is sent to the panel.
Yellow LED
Detector 065 Trouble
Detector 066 Trouble
Detector 067 Trouble
to (see note)
to (see note)
Detector 128 Trouble
Table 22 ACS Group J
Yellow LED
Detector 065 Trouble
Detector 066 Trouble
Detector 067 Trouble
to (see note)
to (see note)
Detector 128 Trouble
Table 23 ACS Group K
Yellow LED
SLC 1, Detector 129 Trouble Not Used
SLC 1, Detector 130 Trouble Not Used
SLC 1, Detector 131 Trouble Not Used
to (see note 1)
to (see note 1)
SLC 1, Detector 159 Trouble Not Used
SLC 2, Detector 129 Trouble Not Used
SLC 2, Detector 130 Trouble Not Used
SLC 2, Detector 131 Trouble Not Used
to (see note 2)
to (see note 2)
SLC 2, Detector 159 Trouble Not Used
Table 24 ACS Group L
NFS-640 Programming Manual P/N 51333:B 10/03/2003
How to Use the Basic Program
Switch Function*
Not Used
Not Used
Not Used
Not Used
Switch Function*
Not Used
Not Used
Not Used
Not Used
Switch Function*