Un it Fau lts
The Thermolator has detected a problem with the internal components, wiring, electrical power, or operat-
ing environment. Without correction, the fault could lead to equipment damage or personal injury if it is
not corrected.
The controller displays an error code indicating the cause of the problem.
The TCU may take automatic control actions, based on the nature of the fault, to best protect the op-
erator and the TCU until the fault is corrected.
If the optional alarm package is installed, the fault strobe will illuminate and the audible alarm will
activate.
Some faults require a power cycle to reset.
Fault
Ph
Err
0
Phase Loss/Rotation Error
NOTE: This
The three-phase electrical power
feature is
being provided to the TCU is
an option
and not
either missing a leg, or has
present on
incorrect phase rotation direction
all models.
(TCU is factory-wired for clock-
wise, L1-L2-L3, phase rotation).
This fault is only present on
TCU's that have the optional
three-phase monitor included.
WARNING: Only qualified elec-
trical service personnel should
examine and correct problems
that require opening the unit's
electrical enclosure or checking
electrical current.
u ALARM LED illuminated.
u Optional strobe, sounder,
dry contacts actuated.
u Pump locks off.
u Heater locks off.
u Cooling valve locks closed.
Power must be cycled to reset
this fault.
(Continued)
Possible Cause
Do you have a dead/low leg in the
incoming three phase power?
If a portable installation, are
different parts of your factory
phased differently?
Solution
Have a qualified electrician check
your three-phase power, and cor-
rect any problems.
Ensure consistent phasing
throughout your facility.
--Or--
Reverse any two incoming power
legs on the TW-P.
See Connecting
the Main Power Source.
Check for proper rotation of
pump.
See Testing the Installa-
tion.