Using The Optional Mold Purge Option - Conair Thermolator TW-S User Manual

Table of Contents

Advertisement

4-20
I
O p e r a t i o n
Usi ng the Optio na l Mo ld Purge Optio n
Only the TW-P Thermolator can be ordered with an optional purge valve (Mold Purge),
which clears the process lines of fluid using compressed air. The valve is operated by an
optional manual purge button on the control panel.
Flow GPM (flash)
Mold
Rapid
Process
Purge
Cool
Cool Down
IMPORTANT: Before purging the process lines, be sure that the cooling water
source feed is closed. If the feed is open and the air line has a higher pressure
than the cooling water, air may be injected into the cooling water system. If the
cooling water pressure is higher than the air line, cooling water may be injected
into the air line.
1
Press STOP
to stop the Thermolator.
2
Shut off the cooling water supply valve.
3
Press MOLD PURGE
The "Purge" LED lights.
The cooling valve is opened.
The time required to clear the process lines of fluid will vary according to the length of the
process piping and the size of the tooling.
4
Release MOLD PURGE
Control Power
Autostart Signal
Pump
Heat
Cool
Coolant Pressure
Temperature Limit
Electrical Phase Error
Heat Error
Process Cool Down
Mold Purge
Rapid Cool
Communications
Remote Heat/Cool
Program Mode
to start purging.
Mold
Purge
to stop purging.
Mold
Purge