P rog ra m Me nu I t e m s
Item Name
Alarm delay for high deviation alarm
Alarm delay for low deviation alarm
Alarm deviation alarm delay after start
Alarm output
Autostart enable
Brownout monitor
Communications Baud rate
1
Communications Modbus ID
1
Communications SPI address
1
Communications type
1
Crash Cool enabled
1
Derivative time
Display units
High deviation alarm limit
Integral time
Low deviation alarm limit
Low pressure bypass enabled
Panel Temperature Alarm
Panel Temperature Readout
Proportional band
Proportional band ratio
Pump run hours
Purge enabled (optional)
1
Remote heat/cool enabled
1
Remote Setpoint enabled
1
Remote Setpoint high limit
1
Remote Setpoint low limit
1
Retransmit high limit
1
Retransmit low limit
1
Return Temperature Probe Enable
Seal-Saver enabled
User high safety limit alarm
User low safety limit alarm
User password
Vent sequence cancel temperature
1
Requires the Premium Controller option (TW-P) as well as the individual option for this function.
Item
Default
Range
Code
Valve
AdH
30
0 to 60 minutes (10 to 60 minutes on program
versions prior to version 1.33)
AdL
30
0 to 60 minutes (10 to 60 minutes on program
versions prior to version 1.33)
ADS
30
0 to 30 minutes on program version 1.33 and later
only
AdO
DIS
Disabled (DIS) or Enabled (EnA) on program
versions 1.33 and later only
ASE
ENA
Disabled (DIS) or Enabled (EnA)
brn
EnA
Disabled (DIS) or Enabled (EnA)
bAU
96
12 to 96
bId
1
1 to 247
SPA
32
32 to 63
COt
OFF
OFF, Retransmit (rEt), SPI (SPI), ModBus (bUS),
Handheld Remote (Han)
CCE
DIS
Disabled (DIS) or Enabled (EnA)
dEr
5
0 to 200
Unt
F
F or C
HId
10
5 to 100 degrees above set point
Int
25
1 to 800
Lod
10
5 to 100 degrees below set point
pbE
dIS
Disabled (DIS) or Enabled (EnA)
PAe
EnA
Disabled (DIS) or Enabled (EnA)
Pte
Display only
bnd
20
1 to 300
Pbr
5
1 to 10
PrH
0
0 to 999 (x100)
PuE
DIS
Disabled (DIS) or Enabled (EnA)
rHC
DIS
Disabled (DIS) or Enabled (EnA)
rSE
DIS
Disabled (DIS) or Enabled (EnA)
rSH
260
rSL to 999
rSL
10
-99 to rSH
rEH
260
rEL to 999
rEL
10
-99 to rEH
SSE
EnA
Disabled (DIS) or Enabled (EnA)
SSE
EnA
Disabled (DIS) or Enabled (EnA)
HSU
260
Between factory low and high limits
LSU
22
Between factory low and high limits
UPA
000
0 to 999
SCt
120
Between factory low and high limits
O per a t i on
I
4-15