5-2
I
M a i n t e n a n c e
Mai nte na n ce o f y our The rmo la to r
Depending on which features, options, and additions you ordered with your Thermolator,
your maintenance procedures and necessities may differ from what is shown in this user
guide. Please note that all illustrations, photos, and instructions are based on a typical
configuration of a Thermolator. Always refer to the wiring diagrams and other documen-
tation - including manuals from the manufacturer of any valves, heat exchangers, and parts
used on your Thermolator - when completing any maintenance or troubleshooting tasks.
If you have any questions or concerns about your Thermolator, feel free to call Conair's
Parts and Service departments for assistance.
Pr even ta ti ve Ma int ena nc e S che dule
Once the unit is in service, we suggest following the maintenance procedures as closely as
possible. The importance of a properly established preventive maintenance program can-
not be overemphasized. Taking the time to follow these simple procedures will result in
substantially reduced downtime, reduced repair costs, and an extended useful lifetime for
the unit. Thermolator TW water temperature controllers are essentially maintenance-free.
However, to maintain the best performance, we recommend the following maintenance
schedule.
Daily or as often as necessary
r Check for leaks in cooling and process lines.
Before and during operation, you should inspect the unit and all plumbing lines
for leaks. If a leak develops, stop the Thermolator and repair it.
r Keep the unit and the area around it clean.
Check for and remove lint, dust, or other obstructions on the unit, especially
around air vent areas. Keep floor around the unit dry. The Thermolator ex-
changes air from in front of, underneath, on top and beside the unit, so make sure
that nothing is against the front, bottom, top or sides of the unit that would stop
proper ventilation around the unit.
Quarterly (every 3 months) or as often as necessary
r Inspect power cords, wires, and electrical connections.
Check for loose or frayed wires, burned contacts, and signs of overheated wires.
Check exterior power cords to the main power source and from the electri-
cal box to the pump and heating elements. Check the ground wire and RTD
connections. Replace any wire that appears damaged or has worn or cracked
insulation.
Every five years
r Replace cooling fan in electrical cabinet.