Pr essur e Switc h Se tting s
Minimum System Pressure Required for System Operation (in psig) for 60 Hz Input Power
(Digit 7 of Part # is B,C, F, A or D)
Heater Capacity
Pump Power (Digit 6 of Part #)
(Digit 7 of Part #)
¾ hp
Description
Digit 7 Value
D
0 kW
0
60
3 kW
A
65
6 kW
B
65
9 kW
C
65
12 kW
D
65
18 kW
E
65
24 kW
F
65
36 kW
G
N/A
48 kW*
H
N/A
Minimum System Pressure Required for System Operation (in psig) for 50 Hz Input Power
(Digit 7 of Part # is E)
Heater Capacity
Pump Power (Digit 6 of Part #)
(Digit 7 of Part #)
½ hp
Description
Digit 7 Value
C
0 kW
0
60
3 kW
A
70
6 kW
B
70
9 kW
C
70
12 kW
D
70
18 kW
E
70
24 kW
F
75
36 kW
G
N/A
48 kW*
H
N/A
Closed Circuit Units at 300 °F {149° C}
1 hp
2 hp
3 hp
5 hp
7½ hp
E
H
J
K
L
60
60
60
60
60
65
65
65
60
60
65
65
65
60
60
65
65
65
60
60
65
65
65
60
60
65
65
65
60
60
60
60
60
60
60
N/A
N/A
N/A
60
60
75
75
75
60
60
¾ hp
1 hp
2 hp
3 hp
5 hp
D
E
H
J
K
60
60
60
60
60
70
70
70
60
60
70
70
70
60
60
70
70
70
60
60
70
70
70
60
60
70
70
70
60
60
70
70
70
75
70
N/A
N/A
N/A
N/A
70
N/A
N/A
N/A
N/A
N/A
(continued)
10 hp
Description
M
Digit 6 Value
60
60
60
60
60
60
60
60
60
7½ hp
Description
L
Digit 6 Value
60
60
60
60
60
60
70
70
N/A