SPI O p tion Pa r am et e rs

Command
Echo
Version
Set Point Process Temperature
Alarm, High Temperature Deviation
Alarm, Low Temperature Deviation
Status, Process
Status, Machine 1
Status, Machine 2
Mode, Machine
Temperature, To Process (Supply)
Temperature, To Process (Return)
Poll
Select
Description
20 20
20 21
Controller integrity command used to accept and retain data and provide it in response to
a poll inquiry in an open 4-byte ASCII format with ASCII units.
20 22
Controller version command used to provide a version number following format: AABB,
where AA=SPI assigned version level, BB=vendor assigned version level in an open
4-byte ASCII format with ASCII units.
20 30
20 31
Target supply coolant temperature leaving the unit in a numeric format in °F.
20 32
20 33
Value in conjunction with the process set point that determines the high alarm tempera-
ture in a numeric format in °F must always be positive.
20 34
20 35
Value in conjunction with the process set point that determines the low alarm tempera-
ture in a numeric format in °F must always be positive.
20 40
Process status in a 16-bit format as follows:
0=controlling
1=an alarm is present
2=an alarm affecting the process has occurred (high or low temperature deviation)
3=an alarm affecting the machine has occurred (probe fault or pump fault)
4=the controller has exceeded its over set point deviation
5=the controller has exceeded its below set point deviation.
20 42
Machine status in a 16-bit format as follows:
0=controlling
1=an alarm is present
2=an alarm affecting the process has occurred (high or low temperature deviation)
3=an alarm affecting the machine operation has occurred (probe fault or pump fault)
4=the controller has exceeded its over set point deviation
5=the controller has exceeded its below set point deviation.
20 44
Machine status in a 16-bit format as follows:
0=controlling
1=an alarm is present
2=an alarm affecting the process has occurred (high or low temperature deviation)
3=a sensor error has been detected
4=an alarm affecting the machine operation has occurred.:
20 48
20 40
Machine mode in two 8-bit bytes. When polling 20 48 bit 0 indicated the machine is off. 20
40 bit 0 commands the unit to be turned on or off (on when high or off when low). 20 40
bit 1 is used to recognized the alarm condition.
20 70
Returns the process supply temperature in a numeric format in °F.
20 72
Returns the process return temperature in a numeric format in °F.
O per a t i on
I
4-17