Specifications: Tw-P; S Pe C If Ic A Ti O Ns : T W- P - Conair Thermolator TW-S User Manual

Table of Contents

Advertisement

S p e c i fica tio n s : TW- P
Models
Performance Characteristics
Minimum setpoint temperature °F {°C}
Maximum setpoint temperature °F {°C}
Minimum operating temperature °F {°C}
Standard cooling valve size inches {mm}
Available pump sizes
Available heater sizes
Connections to/from process NPT (female)
Connections in/out cooling water NPT (female)
Pump Performance -
Consult your Conair representative for pump performance characteristics at other operating points.
Pump
Nominal flow gpm {lpm}
Pressure @ nominal flow psi {kg/cm
Dimensions
inches {mm}
Cabinet Style
Height
Width
Depth
Shipping weight ranges
lb {kg}
Pump
0.75 Hp {0.56 kW}
1 Hp {0.75 kW}
2 Hp {1.49 kW}
3 Hp {2.24 kW}
5 Hp {3.73 kW}
7.5 Hp {5.59 kW}
10 Hp {7.46 kW}
Total Full Load Amps per zone **
Heater
Voltage
208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60 208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60 208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60
Pump size
0.75 Hp {0.56 kW}
25.9
1.0 Hp {0.75 kW}
26.8
2.0 Hp {1.49 kW}
28.9
3.0 Hp {2.24 kW}
31.7
5.0 Hp {3.73 kW}
36.3
7.5 Hp {5.59 kW}
42.1
10.0 Hp {7.46 kW}
50.3
Total Full Load Amps per zone **
Heater
Voltage
208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60 208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60 208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60
Pump size
0.75 Hp {0.56 kW}
63.6
1.0 Hp {0.75 kW}
64.5
2.0 Hp {1.49 kW}
66.6
3.0 Hp {2.24 kW}
69.4
5.0 Hp {3.73 kW}
74.0
7.5 Hp {5.59 kW}
79.8
10.0 Hp {7.46 kW}
88.0
Specification Notes
* Lower operating temperatures can be obtained with larger cooling valves.
Available in TW-S and TW-P models only.
Direct Inject (DI) cooling injects cooling water directly into the process loop upon
demand.
Closed Circuit (CC) cooling injects cooling water into the process loop only during the
§
initial filling or when make-up water is needed.
TW-P (direct injection)
6, 9, 12, 18, 24, 36 or 48 kW
3/4 Hp {0.56 kW} 1 Hp {0.75 kW} 2 Hp {1.49 kW} 3 Hp {2.24 kW} 5 Hp {3.73 kW} 7.5 Hp {5.59 kW} 10 Hp {7.46 kW}
50 {189}
}
20 {1.4}
2
Single Zone (A)
28.43 {722}
14.00 {356}
25.75 {654}
Weights vary depending on cabinet size, options,and cooling type (DI or CC).
Minimum
240 {109}
245 {111}
248 {113}
259 {118}
302 {137}
317 {144}
329 {149}
9 kW
15.0
12.9
10.5
15.2
15.3
13.3
10.6
16.6
16.7
14.3
11.6
13.4
18.0
15.4
12.5
20.7
18.2
17.7
14.2
24.9
20.5
20.3
16.3
28.9
24.8
24.1
18.9
24 kW
36.6
31.7
25.6
36.8
36.9
32.1
25.7
38.2
38.3
33.1
26.7
39.7
39.6
34.2
27.6
42.3
39.8
36.5
29.3
46.5
42.1
39.1
31.4
50.5
46.4
42.9
34.0
40 {4}
250 {121}, (300 {149} optional)
Approximately 20° {11°} above the cooling water inlet temperature*
1/4 {6.35}
0.75, 1, 2, 3, 5, 7.5, 10 Hp {0.56, 0.75, 1.49, 2.24, 3.73, 5.59, or 7.46 kW}
1.50 inches
1.00 inches
55 {208}
75 {284}
85 {322}
25 {1.7}
30 {2.1}
32 {2.2}
Dual Zone (B)
29.00 {734}
28.34 {720}
26.06 {662}
Single Zone
Maximum
280 {127}
290 {132}
298 {135}
299 {136}
352 {160}
362 {164}
379 {172}
12 kW
33.4
19.3
16.7
34.3
19.5
19.6
17.1
36.4
20.9
21.0
18.1
39.2
22.4
22.3
19.2
43.8
25.0
22.5
21.5
49.6
29.2
24.8
24.1
57.8
33.2
29.1
27.9
36 kW
93.7
54.0
46.8
94.6
54.2
54.3
47.2
96.7
55.6
55.7
48.2
99.5
57.1
57.0
49.3
104.1
59.7
57.2
51.6
109.9
63.9
59.5
54.2
118.1
67.9
63.8
58.0
** FLA data for reference purposes only. Does not include any options or accessories
on equipment. For full FLA detail for power circuit design of specific machines and
systems, refer to the electrical diagrams of the equipment order and the nameplate
applied to the machine.
Specifications may change without notice. Consult with a Conair representative for the
most current information.
TW-P (closed circuit)
3/4 {19.05} (varies)
9, 12, 18, 24, or 36 kW
100 {379}
120 {454}
46 {3.2}
56 {3.9}
A
B
Dual Zone
Minimum
Maximum
491 {223}
499 {226}
515 {234}
538 {244}
629 {285}
649 {294}
683 {310}
18 kW
13.5
48.5
28.0
13.6
49.4
28.2
28.3
14.6
51.5
29.6
29.7
15.5
54.3
31.1
31.0
17.2
58.9
33.7
31.2
19.3
64.7
37.9
33.5
21.9
72.9
41.9
37.8
48 kW
37.6
N/A
37.7
N/A
38.7
N/A
39.6
N/A
41.3
N/A
43.4
N/A
46.0
N/A
De s c ri p ti o n
§
150 {568}
65 {4.5}
TW-S and
TW-P only
576 {261}
584 {265}
590 {268}
623 {283}
699 {317}
729 {331}
763 {346}
24.2
19.5
24.5
19.6
25.6
20.6
26.7
21.5
29.0
23.2
31.6
25.3
35.4
27.9
61.9
49.7
62.3
49.8
63.3
50.8
64.4
51.7
66.7
53.4
69.3
55.5
73.1
58.1
I
2-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thermolator tw-p

Table of Contents