Uni t Faul ts
The Thermolator has detected a problem with the internal components, wiring, electrical power, or operat-
ing environment. Without correction, the fault could lead to equipment damage or personal injury if it is
not corrected.
•
The controller displays an error code indicating the cause of the problem.
•
The TCU may take automatic control actions, based on the nature of the fault, to best protect the op-
erator and the TCU until the fault is corrected.
•
If the optional alarm package is installed, the fault strobe will illuminate and the audible alarm will
activate.
•
Some faults require a power cycle to reset.
Fault
brn
Ut
Brownout
The TCU experienced a loss of
power while it was running.
Note: This fault can be selectively
enabled/disabled in the user menu under
parameter
WARNING: Only qualified elec-
trical service personnel should
examine and correct problems
that require opening the unit's
electrical enclosure or checking
electrical current.
u ALARM LED illuminated.
u Optional strobe, sounder,
dry contacts actuated.
u Pump turns off.
u Heater turns off.
u Cooling valve closes.
Push the Fault Silence/Reset
button to reset this fault.
6-20
I
Tr o u b l e sh o o ti n g
(Continued)
brn
.
Possible Cause
Did your facility experience a
power outage?
Is there a disturbance or volt-
age imbalance in your electrical
system?
Solution
Ensure that no other connected
equipment has been adversely af-
fected by the power outage.
Push the Fault Silence/Reset but-
ton, and then push the Run button
to restart the TCU.
Have a qualified electrician review
your facility wiring and electrical
power. Correct any issues so that
the voltage provided to the TCU is
as required.
(Continued)