External Interfaces - Conair Thermolator TW-S User Manual

Table of Contents

Advertisement

External In te r face s
Setting the So f t wa r e
If you ordered the "remote setpoint" option with the TCU, your TCU will come pre-configured to
accept a remote setpoint. This means that you will NOT be able to select a setpoint directly from
the temperature controller (without changing the default parameters). Additionally, the TCU comes
from the factory set to 0-20mA covering the entire range of 10°F to 260°F.
Remote Setpoint Related Parameters
U34
Remote setpoint enabled
U35
Remote setpoint type
U36
Remote setpoint high range
U37
Remote setpoint low range
Process Value Retransmit Analog Output:
If you ordered the "process value retransmit" communication option with the TCU, your TCU will
come pre-configured to accept a remote setpoint. This means that you will NOT be able to select a
setpoint directly from the temperature controller (without changing the default parameters). Addi-
tionally, the TCU comes from the factory set to 0-20mA covering the entire range of 10°F to 260°F.
Process Value Related Parameters
U38
Communications type
U39
Retransmit type
U40
Retransmit high limit
U41
Retransmit low limit
Modb us RT U C o mm un i ca t i on
Connecting to the Thermolator
The Thermolator has a 2-wire (plus common) RS-485 network for Modbus communication.
Pin 4
T+/R+
Pin 5
T-/R-
DB-9 hood
Common
Setting the Modbus Address and Speed
Modbus Related Parameters
U38
Communications type
U42
Communications Baud Rate
U43
Modbus ID
(Continued)
rse
ena
Disabled (lS) or Enabled (En)
rst
nna
4-20mA (nn) or 0-10 Volts (u) (be sure to also
change jumpers)
rsH
2
rSl to 
rS

- to rSH
t
rEt
OFF,
Retransmit (rEt),
ModBus-RTU (bUS),
ModBus-TCP (tcP), or
Handheld Remote (Hn)

NOTE: No SPI communications
rtt
nn
4-20mA (nn) or 0-10 Volts (u)
rtH
2
rSl to 
rt

- to rEH
t
bUS
OFF,
Retransmit (rEt),
ModBus-RTU/TCP (bUS), or
Handheld Remote (Hn)
bU

2 to 
b
 to 24
A ppendi x
I
E-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thermolator tw-p

Table of Contents