HP A6616 Installation Manual page 39

Table of Contents

Advertisement

Table 1-34 FIPs' support for HIMs and MIMs
Interface module
HIM
MIM
State description of FIPs
A FIP can be in one of six states as shown in
Table 1-35 State description of FIPs
Status
Absent
Disable
Fault
Normal
Startup
Wait
Use the display version command to view the state of all slots. For example:
<HP>display device
Slot No.
Board type
---------------------------------------------------------------------
0
FIP-200
1
N/A
2
N/A
3
N/A
4
RPE-X1
5
RPE-X1
6
N/A
7
N/A
8
FIP-200
9
N/A
Table 1-36 display device command output description
Slot No
Board type
Status
Primary
SubSlots
For details about the display device command, refer to Device Management in the System
Volume of HP SR6600 Routers User Manual.
FIP-100
Not supported
Supported
Table
Meaning
Out of position
Powered off through the CLI
Faulty
Normal
Powered on
Wait due to insufficient power
Status
Primary
Startup
N/A
Absent
N/A
Absent
N/A
Absent
N/A
Normal
Slave
Normal
Master
Absent
N/A
Absent
N/A
Normal
N/A
Absent
N/A
Field
FIP-110
Not supported
Supported
Supported
Supported
1-35.
No FIP is installed in a slot of the router.
The user powers off a FIP through the CLI.
The system fails to identify a FIP.
The FIP has completed the startup process and
works normally.
The FIP is being powered on.
The FIP is waiting for being powered on due to
insufficient power.
SubSlots
2
N/A
N/A
N/A
0
0
N/A
N/A
2
N/A
Slot number of the board
Type of the board
Board status
Whether the MPU is in the active state or not.
Number of sub slots
FIP-200
FIP-210
Supported
Supported
Remarks
Description

Advertisement

Table of Contents
loading

Table of Contents