RESET button
To reset the current RPE-X1, you can press the RESET button.
If you press the RESET button when only one RPE-X1 is equipped, the whole system will be
reset.
If you want to perform an active-standby switchover when two RPE-X1s are equipped, press
the RESET button on the active RPE-X1. The system will automatically switch the services to
the standby RPE-X1, without interrupting the ongoing services.
If you press the RESET button on the standby RPE-X1 when two RPE-X1s are equipped, the
standby RPE-X1 will be reset but the system operation will not be affected.
The RUN LED goes off when the RPE-X1 is reset, flashes fast (at 8 Hz) when BootWare is
running, and flashes slowly (at 1 Hz) after the system is booted and operates normally.
If you perform no save operation before resetting the router, the current system configuration
will not be saved after the router is reset.
Never press the RESET button when the RUN LED is blinking fast or when the router is
accessing the CF card or a USB storage device. Otherwise, the file system of the router may be
damaged.
Clock
The device is designed with an internal clock module that provides the system time. You can set
the system time through a command line interface. Use the clock datetime time date command
in user view to set the system date and time. For the description of the clock datetime
command, refer to Basic System Configuration in the System Volume of HP SR6600 Routers
User Manual.
When a power failure occurs to the router, the clock module can continue working to ensure the
system time is correct next time the router boots. With the router powered off, the clock module
can work for at least 10 years.
When the router is powered on, note the following points:
Never replace the clock module battery.
The system time gets lost once the clock module battery is removed, and you need to set the
system time again through the command line interface. However, the system time will still get
lost after the router is powered off.
Switchover between the active and standby MPUs
The device can be equipped with two RPE-X1s. One is active and operates in the master mode,
and the other is standby and operates in the slave mode. By default, the MPU in Slot 5 operates
in the master mode. The configuration of the standby MPU is synchronized with that of the
active MPU. Thus, in the event that the active MPU fails, the standby MPU immediately
becomes active to ensure that the device works properly and its configuration is synchronized
with that of the original active MPU. This process is known as active-standby switchover.
An active-standby switchover occurs when:
The active MPU fails.
The active MPU is removed.
A remote switchover is performed through SNMP.
A manual switchover is performed.
The active-standby switchover process is as follows:
1)
The standby MPU automatically connects and controls the system bus while the original active
MPU disconnects the system bus.
2)
The standby MPU goes active whereas the original active MPU automatically reboots and goes
standby.
You can use the slave switchover command to perform a manual active-standby switchover.
For details about the slave switchover command, refer to HA in the System Volume of HP
SR6600 Routers User Manual.