Printronix SL5000r User Manual page 53

Rfid smart label and thermal printers
Hide thumbs Also See for SL5000r:
Table of Contents

Advertisement

The validator requires a minimum distance of 1/2" or 20 times the minimum
NOTE:
element width (x-dimension), whichever is greater, between bar codes.
When set to Enable (the default), then the bar code quiet zone is included as part of the
pass/fail criteria.
. .
.
1. Press
to take the printer offline and place the printer in Menu mode.
2. If necessary, press and
. .
3. Press
until VALIDATOR displays.
.
4. Press until Quiet Zones displays.
5. Press + or – to scroll through the choices: Enable or Disable. The default is Enable.
6. Press
to select the desired value.
7. Press  and
at the same time to lock the
printer offline.
8. Press PAUSE again to put the printer online.
NOTE:
The validator does not recognize x-dimensions greater than 40 mil with Quiet
Zones enabled.
Checking the Firmware Revision Number
For troubleshooting purposes, you may need to reference the firmware revision
number.
. .
1. Press
.
to take the printer offline and place the printer in Menu mode.
2. If necessary, press and
. .
3. Press
.
until VALIDATOR displays.
4. Press until F/W Revision displays. The firmware revision number displays.
5. Press  and
at the same time to lock the
printer offline.
6. Press PAUSE again to put the printer online.
Setting for Skip Labels
This option is used for skipping blank labels after bad labels have been marked. It is
useful when you want to have extra blank labels in between bad and good ones. The
settings are Minimum (the default) and Maximum. Minimum allows up to one blank
label, and Maximum allows up to two blank labels.
NOTE:
Minimum and Maximum blank labels are only applicable for forms 2 inches
(5.08 cm) high or more. For labels less than 2 inches high, the minimum and
maximum blank labels may vary.
. .
1. Press
.
to take the printer offline and place the printer in Menu mode.
2. If necessary, press and
. .
3. Press
.
until VALIDATOR displays.
4. Press  until Skip Labels displays.
at the same time to unlock the
key, then press PAUSE to take the
at the same time to unlock the
key, then press PAUSE to take the
at the same time to unlock the
key.