KPA080 Ku-Band Solid-State Power Amplifier
5.7.5
Device Address
The Device Address consists of a Physical Address. For this document DEV is used for
the generic case examples.
5.7.6
Command
A Command is a variable length character string beginning with a / and containing either
an instruction or an instruction and data for an SSPA to act upon.
5.8
Confirmation Response
A confirmation will change the start character, and echo the Device Address and
Command. Any requested data will be appended to the Command.
5.8.1
Error Response
If an SSPA cannot execute a Command or detects a protocol violation, an error response
is generated. An error is flagged by changing the "/" command designator in the response
to a "?". Following the "?" error symbol are two characters which are unique error
symbols useful for computer analysis. The two error symbols are followed by a text
string explaining the error for the convenience of a human operator. For this document
ER is used for the generic case examples response.
Rev. 0
For Example;
<10
<10V2
•
If data is passed by command, it is appended to the instruction by an
underscore( _ ).
•
If data is retrieved by command, underscore follows the instruction flagging
the SSPA to supply data in a response.
•
In this document /COM is used for the generic case examples.
For Example:
<DEV/COM_xxx'cr'
For Example:
<DEV/COM_'cr'
For Example:
For Example:
direct addressing
indirect addressing
Sends data to an SSPA.
Requests information from an
SSPA.
>DEV/COM_xxx'cr''lf']
>DEV?COM ER Error Message 'cr''lf']
Remote Control
5-7