Remote Control
5.5
Protocol
Refer to Table 5-1 for protocol description. Protocol is divided into six subjects:
5.5.1
Format
The following parameters are the default character format:
Start Bit
Parity Bit
Stop Bits
Data Bits
An optional character format that can be selected is:
Note: This can only be selected from the Front Panel Menu.
Parity Bit
Start Bit
Stop Bit
Data Bits
5-4
•
Transmission Mode
•
Baud Rate
•
Format
•
Character Set
•
Response Timeout
•
Bus Inactivity Requirements
Transmission Mode
The transmission mode is half-duplex implemented in
Command/Response convention. This method requires the external
system monitor and control unit to initiate all communications by
command and the SSPA to respond with either confirmation or an error
message. The confirmation may contain status information.
Baud Rate
The default serial port Baud Rate is 9600.
Baud rates of 4800, 2400, 1200, and 300 also are supported.
Character Set
The character set implemented is ASCII.
Response Timeout
A minimum of 500 milliseconds should be provided before declaring a
No Reponse instance, at which time the command should be
re-transmitted.
Bus Inactivity
COMTECH EFData recommends that a minimum of 50 milliseconds
Requirement
bus inactivity be provided by the user between the receipt of a response
from an addressed SSPA and issuing the next command on the serial
bus.
1
1 (Selectable, Even or Odd, via the front panel menu or remote interface
2
7
0
1
1
8
KPA080 Ku-Band Solid-State Power Amplifier
Table 5-1. Protocol Description
Rev. 0