Model
Indicator Lamps
Power voltage
Consumption current
Environmental
specifications
Weight
Dimensions
Accessories
LED class
Safety standards
Material
*1. These are the code types supported based on Omron's read capability validation standard. It is recom-
mended that the customer do its own validation in its actual work environment.
*2. Unless otherwise specified, the reading performance is defined with center of field of view, angle R=∞.
Auto Focus Multi Code Reader V430-series User's Manual (Z392)
V430-F000 50C
PASS (Green), TRIG (Amber), MODE (Amber), LINK (Amber),
FAIL (Red), PWR (Green)
5.0 to 30.0 VDC (including ripple)
0.18A (typ.) (at 24VDC)
Ambient
Operating: 0 to 40°C, Storage: -50 to +75°C (with no icing or con-
temperature
densation)
range
Ambient
Operating: 5 to 95%RH, Storage: 5 to 85%RH (with no condensa-
humidity range
tion)
Ambient
No corrosive gases
atmosphere
Vibration
10 to 55 Hz, double amplitude: 0.35 mm, X/Y/Z directions, 10
Resistance
cycles/axis
(destruction)
Shock resis-
tance
150 m/s
(destruction)
Degree of
IEC 60529 IP67
protection
Main body
Approx. 68 g
only
Packing
Approx. 174 g
weight
Main body
44.5 (W) × 44.5 (D) × 25.4 (H) mm
Dimension
Packing
170 (W) × 117 (D) × 86 (H) mm
Dimension
Instruction manual("Read me first"), Compliance Sheet (CE)
Risk Group Exempt (IEC 62471-1)
EN61326-1: 2013
FCC Part 15, Subpart B (Class A)
UL60950-1
Case
Aluminum diecast, alumite (black)
Reading win-
Acrylic
dow
V430-F000 12M
2
, 3 times in each X/Y/Z directions
Appendices
V430-F
M03M
A-3