Omron V430-F-series User Manual page 197

Auto focus multi code reader
Table of Contents

Advertisement

ISO/IEC 15415 Symbol Quality Output 1
Modulation Threshold
Usage:
Sets the threshold for driving the output.
Definition:
Conforms to ISO/IEC 15415 symbol quality grading (A,B,C,D).
Serial Cmd:
<K870, output on overall grade, overall grade threshold, symbol contrast,
symbol contrast threshold, modulation, modulation threshold, reflectance
margin, reflectance margin threshold, fixed pattern damage, fixed pattern
damage threshold, axial non-uniformity, axial non-uniformity threshold, grid
non-uniformity, grid non-uniformity threshold, unused ECC, unused ECC
threshold>
Default:
Grade B
Options:
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Reflectance Margin
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, drives Output if grade is under Reflectance Margin Threshold.
Serial Cmd:
<K870, output on overall grade, overall grade threshold, symbol contrast,
symbol contrast threshold, modulation, modulation threshold, reflectance
margin, reflectance margin threshold, fixed pattern damage, fixed pattern
damage threshold, axial non-uniformity, axial non-uniformity threshold, grid
non-uniformity, grid non-uniformity threshold, unused ECC, unused ECC
threshold>
Default:
Disabled
Options:
0 = Disabled
7-32
1 = Enabled