Omron V430-F-series User Manual page 146

Auto focus multi code reader
Table of Contents

Advertisement

Large Intercharacter Gap (Codabar)
Definition:
When disabled, the spaces between characters, or the "intercharacter
gap", are ignored during the decode process.
Note: If the intercharacter space is large enough to be considered a margin,
the symbol will not decode, regardless of this parameter's setting.
Serial Cmd:
<K471,status,start/stop match,start/stop output,large intercharacter
gap,fixed symbol length status,symbol length,check character type,check
character output>
Default:
Disabled
Options:
0 = Disabled
Fixed Symbol Length Status (Codabar)
Definition:
When disabled, the reader will accept any Codabar symbol provided it
doesn't exceed the system's maximum capabilities.
When enabled, the reader will reject any Codabar symbol that doesn't
match the fixed length.
Serial Cmd:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed
symbol length status,symbol length,check character type,check character
output>
Default:
Enabled
Options:
0 = Disabled
Symbol Length (Codabar)
Definition:
This is the value against which all Codabar symbol lengths will be compared.
Serial Cmd:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed
symbol length status,symbol length,check character type,check character
output>
Default:
10
Options:
1 to 64
Auto Focus Multi Code Reader V430-series User's Manual (Z392)
1 = Enabled
1 = Enabled
Symbologies
6-21