Omron V430-F-series User Manual page 274

Auto focus multi code reader
Table of Contents

Advertisement

Sequence on Mismatch
Note: Matchcode must be set to Sequential for this command to function.
Usage:
Enable this parameter if every trigger event should have a decode and
more than one consecutive mismatch may occur.
Disable this parameter if every trigger event should have a decode but
no more than one consecutive mismatch may occur.
Definition:
When set to Enabled, the master symbol sequences on every decode,
match, or mismatch.
When set to Disabled, the master symbol will not sequence whenever
consecutive mismatches occur.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match
length,wild card character,sequence on No-Read,sequence on mismatch>
Default:
Disabled
Options:
0 = Disabled
The reader will sequence the master to one more or one less than the decoded symbol.
As an example of Sequence on Mismatch Enabled, consider the following decodes:
Master Symbol
001
002
003
004
005
006
007
As an example of Sequence on Mismatch Disabled, consider the following decodes:
Master Symbol
001
002
003
004
005
006
006
Auto Focus Multi Code Reader V430-series User's Manual (Z392)
Decoded Symbol
001
002
abc
004
def
ghi
007
Decoded Symbol
001
002
abc
004
def
ghi
006
1 = Enabled
Master Symbol after Decode
002
003
004 (sequenced on mismatch)
005
006 (sequenced on mismatch)
007 (sequenced on mismatch)
008
Master Symbol after Decode
002
003
004 (sequenced because of previous match)
005
006 (sequenced because of previous match)
006 (not sequenced)
007
Matchcode
9-9