Omron V430-F-series User Manual page 183

Auto focus multi code reader
Table of Contents

Advertisement

Setup Button
Default on Power-On
Definition:
When enabled, if the Setup button is held down on power-on the imager
will default to customer defaults and save for power-on. This is the same
as sending a <Zrc> command.
Serial Cmd:
<K770,global status,default on power-on,load Configuration Database,
save for power-on>
Default:
Enabled
Options:
0 = Disabled
Load Configuration Database
Definition:
Allows the user to load the Configuration Database with calibration results.
When the user performs a calibration using the Setup button, all the data-
base entries are moved down one index and the results of the calibration
are saved to index 1. The results will be saved as current settings as well.
Serial Cmd:
<K770,global status,default on power-on,load Configuration Database,
save for power-on>
Default:
Enabled
Options:
0 = Disabled
Save for Power-On
Definition:
If enabled, after calibration is complete, all parameters will be saved for
power-on.
Serial Cmd:
<K770,global status,default on power-on,load Configuration Database,
save for power-on>
Default:
Disabled
Options:
0 = Disabled
7-18
1 = Enabled
1 = Enabled
1 = Enabled
Auto Focus Multi Code Reader V430-series User's Manual (Z392)