Omron V430-F-series User Manual page 204

Auto focus multi code reader
Table of Contents

Advertisement

Serial Cmd:
<K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet Zone,
quiet zone threshold >
Default:
Disabled
Options:
0 = Disabled
Decode Threshold
Usage:
Sets the threshold for driving the output.
Definition:
Conforms to ISO/IEC 15416 symbol quality grading (A,B,C,D).
Serial Cmd:
<K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet Zone,
quiet zone threshold >
Default:
Grade B
Options:
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Contrast
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, drives Output if grade is under Contrast Threshold.
Serial Cmd:
<K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet Zone,
quiet zone threshold >
Default:
Disabled
Options:
0 = Disabled
Auto Focus Multi Code Reader V430-series User's Manual (Z392)
1 = Enabled
1 = Enabled
I/O Parameters