Morphological Operation and Operator Size
Open (Connect Dark)
Open removes minor light defects of dark cells by performing a Dilate function followed by
an Erode function.
Close (Separate Dark)
Close removed minor dark defects of light cells by performing an Erode function followed
by a Dilate function.
10-24