Print Growth Threshold
Usage:
Lets the user set the acceptable level of symbol quality.
Definition:
Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd:
<K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default:
Grade C
Options:
0 = Grade A
1 = Grade B
2 = Grade C
3 = Grade D
Axial Non-Uniformity Threshold
Usage:
Lets the user set the acceptable level of symbol quality.
Definition:
Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd:
<K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default:
Grade C
Options:
0 = Grade A
1 = Grade B
2 = Grade C
3 = Grade D
Unused Error Correction Threshold
Usage:
Lets the user set the acceptable level of symbol quality.
Definition:
Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd:
<K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default:
Grade C
Options:
0 = Grade A
1 = Grade B
2 = Grade C
3 = Grade D