ISO/IEC 15416 Symbol Quality Output 1
Default:
Grade B
Options:
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Edge Determination
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, drives Output if grade is under Edge Determination Thresh-
old.
Serial Cmd:
<K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet Zone,
quiet zone threshold >
Default:
Disabled
Options:
0 = Disabled
Edge Determination Threshold
Usage:
Sets the threshold for driving the output.
Definition:
Conforms to ISO/IEC 15416 symbol quality grading (A,B,C,D).
Serial Cmd:
<K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet Zone,
quiet zone threshold >
Default:
Grade B
Options:
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Decode
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, drives Output if grade is under Decode Threshold.
7-38
1 = Enabled