Symbol Quality Separator/Output Mode
Output Mode
Note: Output Mode applies to ISO/IEC 16022 symbol quality parameters, ISO/IEC 15415 sym-
bol quality parameters, ISO/IEC 15416 symbol quality parameters, and ISO/IEC 29158 symbol
quality parameters.
Definition:
Output Mode specifies how the output parameters, if enabled, are format-
ted.
Serial Cmd:
<K708,symbol quality separator,output mode>
Default:
Grade
Options:
0 = Grade
Grade
If in Grade Mode, a grade (A,B,C,D,F) is appended to the symbol data.
Value
If in Value Mode, the calculated value for the given parameter is appended to the symbol data.
Score
If in Score Mode, a percentage of passing lines for that parameter is appended to the symbol
data.
8-6
1 = Value
Auto Focus Multi Code Reader V430-series User's Manual (Z392)
2 = Score