Omron V430-F-series User Manual page 208

Auto focus multi code reader
Table of Contents

Advertisement

Serial Cmd:
<K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet
Zone, quiet zone threshold >
Default:
Grade B
Options:
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Decodability
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, drives Output if grade is under Decodability Threshold.
Serial Cmd:
<K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet
Zone, quiet zone threshold >
Default:
Disabled
Options:
0 = Disabled
Decodability Threshold
Usage:
Sets the threshold for driving the output.
Definition:
Conforms to ISO/IEC 15416 symbol quality grading (A,B,C,D).
Serial Cmd:
<K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet
Zone, quiet zone threshold >
Default:
Grade B
Options:
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Auto Focus Multi Code Reader V430-series User's Manual (Z392)
1 = Enabled
I/O Parameters
7-43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents