ISO/IEC 15415 Symbol Quality Output 1
Options:
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Axial Non-uniformity
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, drives Output if grade is under Axial Non-uniformity Thresh-
old.
Serial Cmd:
<K870, output on overall grade, overall grade threshold, symbol contrast,
symbol contrast threshold, modulation, modulation threshold, reflectance
margin, reflectance margin threshold, fixed pattern damage, fixed pattern
damage threshold, axial non-uniformity, axial non-uniformity threshold,
grid non-uniformity, grid non-uniformity threshold, unused ECC, unused
ECC threshold>
Default:
Disabled
Options:
0 = Disabled
Axial Non-uniformity Threshold
Usage:
Sets the threshold for driving the output.
Definition:
Conforms to ISO/IEC 15415 symbol quality grading (A,B,C,D).
Serial Cmd:
<K870, output on overall grade, overall grade threshold, symbol contrast,
symbol contrast threshold, modulation, modulation threshold, reflectance
margin, reflectance margin threshold, fixed pattern damage, fixed pattern
damage threshold, axial non-uniformity, axial non-uniformity threshold,
grid non-uniformity, grid non-uniformity threshold, unused ECC, unused
ECC threshold>
Default:
Grade B
Options:
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Grid Non-uniformity
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, drives Output if grade is under Grid Non-uniformity Thresh-
old.
7-34
1 = Enabled