Symbol Length #1 (Interleaved 2 of 5)
Usage:
Useful in applications where I 2/5 symbols of a specific length are
required.
Definition:
The Symbol Length # 1 field is one of two fields against which the
decoded symbol is compared before accepting it as valid or rejecting it.
Serial Cmd:
<K472,status,check character status,check character output,symbol length
#1,symbol length #2,guard bar status,range mode status>
Default:
16
Options:
0 to 64, even only
Important: If Range Mode is disabled, the length of the symbol must
match either Symbol Length # 1 or Symbol Length # 2 to be considered
a valid symbol.
If Range Mode is enabled, Symbol Length # 1 and Symbol Length # 2
form a range into which the length of the symbol must fall to be considered
valid.
Symbol Length #2 (Interleaved 2 of 5)
Usage:
Useful in applications where I 2/5 symbols of a specific length are
required.
Definition:
The Symbol Length # 2 field is one of two fields against which the
decoded symbol is compared before accepting it as valid or rejecting it.
Serial Cmd:
<K472,status,check character status,check character output,symbol length
#1,symbol length #2,guard bar status,range mode status>
Default:
6
Options:
0 to 64, even only
Important: If Range Mode is disabled, the length of the symbol must
match either Symbol Length # 2 or Symbol Length # 1 to be considered
a valid symbol.
If Range Mode is enabled, Symbol Length # 2 and Symbol Length # 1
form a range into which the length of the symbol must fall to be considered
valid.