LED Configuration

Usage:
Useful as a visible indicator of read rates and symbol quality.
Definition:
Determines the mode in which the status LEDs operate.
Serial Cmd:
<K737,LED mode,ISO/IEC 16022 grade>
Default:
Standard
Options:
0 = Standard
In ISO/IEC 16022 grade mode the LEDs represent the grade of the first Data Matrix
symbol decoded in the read cycle.
The parameter to be graded is set in the ISO/IEC 16022 Grade options.
For example, to program the LEDs to indicate the ISO/IEC 16022 print growth grade, set
LED Mode to ISO/IEC 16022 Grade and set ISO/IEC 16022 Grade to Print Growth. If all
the LEDs from 20% to 100% are illuminated, the read result is a grade A; if only the 20%
LED is illuminated, the result is a grade F.
Standard
In Standard Mode, the STATUS LED indicates read cycle status and the GOOD READ
LED illuminates upon a good read at the end of a read cycle. In a read rate test, these
LEDs represent the percentage of good reads per images captured.
ISO/IEC 16022 Grade
Usage:
Provides visual grading of specific ISO/IEC 16022 parameters.
Definition:
Determines which ISO/IEC 16022 parameter the reader will grade via the
LEDs.
Serial Cmd:
<K737,LED mode,ISO/IEC 16022 grade>
Default:
Final Grade
Options:
0 = Final Grade
1 = Symbol Contrast
2 = Print Growth
3 = Axial Non-Uniformity
4 = Unused ECC